- Button
- (1) Factory reset
- Format
- ISO 7810 ID-1
- Weight
- 363 g (12.8 oz)
- Sensors
- Proximity sensor
- Speaker
- (1) Yes, 0.7W
- Mounting
- DIN-rail (Included)
- Dimensions
- 174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3")
- In The Box
- (1) Door Hub (1) G2 Reader (10) Access Cards
- Connectivity
- BLE 4.1, NFC
- Power Method
- PoE++, UL 294 Power-limited Class 2 PSU, UL 60950-1/62368-1 LPS/PS2 PSU
- UL 294 Level
- Destructive attack: Level I, Line security: Level I, Endurance: Level I, Standby power: Level I
- Digital Input
- Request to exit, request to enter, remote release, door position sensor
- Mobile Unlock
- Yes
- NFC Frequency
- 13.56 MHz
- Po E Interface
- (1) PoE++ input, 50V DC, 1A (4) PoE outputs, 50V DC, 30W per port (Max 45W aggregated)
- Certifications
- CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
- Mount Material
- Polycarbonate
- NDAA Compliant
- Yes
- NFC Read Range
- < 30 mm (1.18'')
- NFC Technology
- ISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340), MIFARE Classic / MIFARE DESFIRE, Sony FeliCa™ (ID only), NFC Forum tags T1T, T2T, T3T, T4T and T5T
- Input Terminals
- (2) Door exit request (1) Door position (1) Emergency
- Supported Doors
- 1
- Weatherproofing
- IP55
- Dry Output Relay
- Lock: 30V DC, 1A, Aux: 30V DC, 1A
- UL 294 Statement
- Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294., The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
- Button (G2 Reader)
- (1) Factory reset
- ESD/EMP Protection
- Air: ± 15kV, contact: ± 8kV
- Enclosure Material
- Polycarbonate
- Weight (G2 Reader)
- 82 g (2.9 oz)
- Mounting (G2 Reader)
- In-wall, gang box (Included), Junction box (Optional)
- Networking Interface
- (5) 10/100/1000 Base-T
- Powered Output Relay
- Lock: 12V DC, 1A, Aux: 12V DC, 0.33A, 12V DC, 0.33A
- Weight (Access Card)
- 5 g (0.18 oz)
- Dimensions (G2 Reader)
- 93 x 40 x 36.5 mm (3.7 x 1.6 x 1.4")
- Indoor And Outdoor Use
- Yes
- Management Application
- UniFi Access
- Max. Power Consumption
- 30W (Without PoE output), 50W (With PoE output)
- Supported Voltage Range
- 48V DC
- CAN/ULC-60839-11-1 Grade
- Grade assignment: 1
- Dimensions (Access Card)
- 85.6 x 53.98 x 0.84 mm (3.37 x 2.13 x 0.03")
- Handwave Request To Exit
- Yes
- NFC Card & Keyfob Access
- Yes
- Po E Cabling Requirements
- Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site., The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
- Power Method (G2 Reader)
- PoE, UL 294 Power-limited Class 2 PSU, UL 60950-1/62368-1 LPS/PS2 PSU
- UL 294 Level (G2 Reader)
- Destructive attack: Level I, Line security: Level I, Endurance: Level I, Standby power: Level I
- Ambient Operating Humidity
- 5 to 95% noncondensing
- Certifications (G2 Reader)
- CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
- Mount Material (G2 Reader)
- Aluminum alloy
- NDAA Compliant (G2 Reader)
- Yes
- NFC Frequency (Access Card)
- 13.56 MHz
- NDAA Compliant (Access Card)
- Yes
- NFC Technology (Access Card)
- ISO/IEC 14443 Type A, MIFARE DESFire, UniFi Access Proprietary Security Protocol
- UL 294 Statement (G2 Reader)
- Compliance with IEEE 802.3 specifications was not verified as part of UL 294., The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
- Ambient Operating Temperature
- 0 to 40° C (32 to 104° F)
- Enclosure Material (G2 Reader)
- Polycarbonate, glass
- Networking Interface (G2 Reader)
- (1) 10/100 MbE RJ45 port
- Management Application (G2 Reader)
- UniFi Access
- Max. Power Consumption (G2 Reader)
- 5W
- CAN/ULC-60839-11-1 Grade (G2 Reader)
- Grade assignment: I
- Po E Cabling Requirements (G2 Reader)
- Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site., The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
- Ambient Operating Humidity (G2 Reader)
- 5 to 90% noncondensing
- Ambient Operating Temperature (G2 Reader)
- -30 to 45° C (-22 to 113° F)
- Recommend Max. Cable Length · Other Locks (1A)
- 24 AWG length: 9 m (30 ft), 22 AWG length: 15 m (49 ft), 20 AWG length: 24 m (79 ft), 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
- Document Number, And Issue Date And/Or Revision Level
- UA-Hub-Door002, V01
- Recommend Max. Cable Length · UA-Lock-Electric (400m A)
- 24 AWG length: 25 m (82 ft), 22 AWG length: 42 m (138 ft), 20 AWG length: 66 m (217 ft), 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
- Recommend Max. Cable Length · UA-Lock-Magnetic-270kg (800m A)
- 24 AWG length: 12 m (39 ft), 22 AWG length: 20 m (66 ft), 20 AWG length: 30 m (98 ft), 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
- Recommend Max. Cable Length · UA-Lock-Magnetic-540kg (500m A)
- 24 AWG length: 20 m (66 ft), 22 AWG length: 32 m (105 ft), 20 AWG length: 51 m (167 ft), 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
- Document Number, And Issue Date And/Or Revision Level (G2 Reader)
- UA-G2/UA-G2-Black, V02